AquaWiz PH probe for KH controller (10496V)

Product no.: 146014

AquaWiz PH probe for KH controller (10496V)
--

Note:

  • When LF 100 is displayed, the pH probe's service life is at 100%.
  • If it is less than 100, you should be prepared to replace the pH probe.
  • It takes about a week for it to drop to zero, which means it is no longer working.
  • When replacing the pH probe, wait about 3 minutes.
  • The display of [Error] indicates that either the pH probe is not plugged in or there is a break in the pH probe circuit.

Inserting the pH probe:

  • Remove the pH probe from its storage bottle and check for cracks in the glass bulb or electrolyte leaks.
  • The pH glass bulb is extremely fragile.
  • Open the top cover of the controller, carefully insert the pH probe into the hole in the left test tube, and lift the left air stone to ensure that it does not come into contact with the pH glass head.
  • Ensure that the pH glass head is about 0.5 cm above the bottom of the test tube to prevent breakage.
  • Plug the pH connector into the rear BNC socket.
  • Close the top cover and tighten the screws securely.
  • After inserting the pH probe, wait 3 minutes;
  • during A6, the LCD should display “LF 100” normally.
  • If “LF 0” or “Error” is displayed, there is a malfunction; please replace it.
  • The pH probe's service life is displayed hourly on the website;
  • do not judge the condition of the new pH probe based on this information on the website.